logo
player background
live avator

5s
Total
0
Today
0
Total
0
Today
0
  • What would you like to know?
    Company Advantages Sample Service Certificates Logistics Service
Online Chat WhatsApp Inquiry
Auto
resolution switching...
Submission successful!
Shenzhen Ruifujie Technology Co., Ltd.
0086 13510281542

refrigerator tools

Found 87 Các sản phẩm

Chất lượng Manual Power  refrigeration controls Crankcase Pressure Regulaor model KVLseries  KVL12 034L0041 nhà máy

Manual Power refrigeration controls Crankcase Pressure Regulaor model KVLseries KVL12 034L0041

refrigeration controls Crankcase Pressure Regulaor model KVL Specifications: Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. The KVL protects the compressor motor against overload during start-up after long standstill periods or after defrost periods. ...

Chất lượng Compressor Capacity Regulator Refrigeration controls KVC Series KVC15 034L0147 nhà máy

Compressor Capacity Regulator Refrigeration controls KVC Series KVC15 034L0147

Refrigeration controls Capacity Regulators KVC Series Specifications: Capacity Regulators A capacity regulator is used for the adaption of the compressor Capacity to the actual evaporator load. They are placed in a by-pass between high and low pressure sides Of the refrigeration plant. In this ...

Chất lượng Professional Refrigeration Controls  Capacity Regulator Model CPCE series CPCE15 034N0083 nhà máy

Professional Refrigeration Controls Capacity Regulator Model CPCE series CPCE15 034N0083

Refrigeration controls Capacity Regulator Model CPCE LG Specifications: Capacity Regulators A capacity regulator is used for the adaption of the compressor Capacity to the actual evaporator load. They are placed in a by-pass between high and low pressure sides Of the refrigeration plant. In this ...

Chất lượng Water Valves Condensing Pressure Refrigeration Controls WVFX10 003N1105 CE R22,R134a,R404A,R12,R502 nhà máy

Water Valves Condensing Pressure Refrigeration Controls WVFX10 003N1105 CE R22,R134a,R404A,R12,R502

Water Valves Condensing Pressure Regulators WVFX10 003N1105 Specifications: Pressure controlled water valves types WVFX are used for regulating the flow of water in refrigeration plant with water-cooled condensers. The water valves give modulating regulation of the condensing pressure and so ...

Chất lượng Manual Power Capacity Refrigeration Controls KVC15 034L0147 Refrigeration Controls R22/R134A/R507 nhà máy

Manual Power Capacity Refrigeration Controls KVC15 034L0147 Refrigeration Controls R22/R134A/R507

Capacity Regulators KVC15 034L0147 Specifications: Capacity Regulators A capacity regulator is used for the adaption of the compressor Capacity to the actual evaporator load. They are placed in a by-pass between high and low pressure sides Of the refrigeration plant. In this position they impose a ...

Chất lượng Orifice assembly Refrigeration Compressor Parts Thermostatic Expansion Valves Orifice NO.0-6 nhà máy

Orifice assembly Refrigeration Compressor Parts Thermostatic Expansion Valves Orifice NO.0-6

Orifice assembly Refrigeration Compressor Parts Thermostatic Expansion Valves Product Description Thermostatic Expansion Valves Orifice Origional orifice for thermostatic expansion valve Orifice no. (TR) Ratedcapacityintons(TR) kW Ratedcapacity inkW Code No. R22 R407C R134a R404A R507 R12 R502 R22 ...

Chất lượng KP1 Series Refrigeration Compressor Parts Low pressure control , 8-32 bar range nhà máy

KP1 Series Refrigeration Compressor Parts Low pressure control , 8-32 bar range

KP1 Series Refrigeration Compressor Parts Low pressure control , 8-32 bar range Specifications: Pressure controls are pressure-activated switches,with a basic function to make or break an electrical circuit which in tur controls a solenoid coil, a contactor or some other functioning part of the ...

Chất lượng  Refrigeration Solenoid Valves EVR3 code 032F8116 nhà máy

Refrigeration Solenoid Valves EVR3 code 032F8116

Refrigeration Solenoid Valves EVR3 code 032F8116 Specifications: Solenoid valves are electrically- controlled open or closed refrigerant flow controlvalves designed for use in liquid, suction and hot gas lines. A normally closed solenoid valve is closed when the coil is de-energised and the plunger ...

Chất lượng TX2 Refrigeration Compressor Parts Refrigeration Valves Therm  Expansion Valve 068Z3206 R404A/R22/R507/R407C nhà máy

TX2 Refrigeration Compressor Parts Refrigeration Valves Therm Expansion Valve 068Z3206 R404A/R22/R507/R407C

TX2 Series Valves / Therm Expansion Valve TX2 068Z3206 Specifications: R22/R407C 3/8in*1/2in Angleway Flare Regriratant:R404A/R22/R507/R407C Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. The flow is controlled by the valve is thermal bulb which is Attached ...

Chất lượng TX2 068Z3206  Series  Refrigeration Valves (068Z3206) R22 CE/ROHS/FCC/SGS -40/+10 nhà máy

TX2 068Z3206 Series Refrigeration Valves (068Z3206) R22 CE/ROHS/FCC/SGS -40/+10

Tes20 Series Refrigeration Valves ( 067b3352 ) R404a / R507 Specifications: thermostatic expansion valves(Tex2) Regriratant: R22/R404A/R507 Thermal expansion valve, expansion valve,thermostatic expansion valve,A/C expansion valve Type TEX2 belong the Outer balance Thermostatic expansion valve ...

Chất lượng Expansion Thermostatic Valves TS2 068Z3400 R404A R507  Refrigeration Parts CE/ROHS/FCC/SGS nhà máy

Expansion Thermostatic Valves TS2 068Z3400 R404A R507 Refrigeration Parts CE/ROHS/FCC/SGS

Expansion Thermostatic Valves TS2 068Z400 R404A R507 Regriratant: R404A/R507 Specifications: 1. Regriratant:R404A/R507/R22/R134a/R12/R502 2.Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. 3.The flow is controlled by the valve is thermal bulb which is ...

Chất lượng Refrigeration Thermostatic expansion  Valves Model TE55 of Brass nhà máy

Refrigeration Thermostatic expansion Valves Model TE55 of Brass

Model TE55 - With Interchangeable Orifice Assembly Specifications: Regriratant:R404A/R22/R134a Thermostatic expansion valve regulate the flow of refrigerant liquid into The evaporator. The flow is controlled by the valve is thermal bulb which is Attached to the suction line at the outlet of the ...

Prev 1 2 3 4 5 Next