Refcomp 95HP 71KW SW3L-9500 Screw Refrigeration Compressor for Freezing Room
SW3L-9500 screw refrigeration compressor
,71KW screw compressor for freezing room
,95HP screw type compressor
-
Optimized Asymmetric Rotor Design
RefComp's 5/6 asymmetric rotor profile helps the screw refrigeration compressor achieve smooth compression while reducing gas pulsation, vibration and operating noise.
-
Precision Bearing System
The semi-hermetic screw compressor uses a multi-bearing arrangement to support axial and radial rotor loads. High-precision bearing components and dedicated lubrication passages help reduce friction and mechanical noise.
-
High-Density Suction Filtration
A built-in 100 μm suction filter removes impurities from incoming refrigerant gas, helping protect the motor and maintain clean refrigerant flow in low-temperature screw compressor applications.
-
INT69 SNY Motor Protection
The INT69 SNY protection module works with six series-connected PTC thermistors to monitor motor temperature and provide protection against overheating, reverse rotation and phase loss.
| Parameter | Value |
|---|---|
| Model | SW3L-9500 |
| Rated power | 95HP / 71KW |
| Exhaust volume 50/60Hz | 318 / 382 m³/hr |
| Weight | 525 Kg |
| Capacity Regulation | 100%, 75%, 50%, 25% (stepless 100%–25%) |
| Standard motor | Y/△ – 400V/3/50Hz – 460/3/60Hz |
| LRA Y/Δ | 318 / 953 A |
| Max Operating Current | 154 A |
Q1: How should compressor capacity regulation be matched to changing refrigeration loads?
The SW3L series supports four-step capacity regulation or stepless adjustment from 25% to 100%. For an industrial refrigeration screw compressor, select the control method according to actual load variations and system controller compatibility.
Q2: What should be checked before commissioning the motor starter?
Verify that the power supply matches the motor requirements, and check the star-delta starter wiring, phase sequence and electrical protection settings before startup.
Q3: What should be confirmed before changing the refrigerant or lubricant?
For a semi-hermetic refrigeration compressor, confirm refrigerant approval and lubricant compatibility with the manufacturer before making any system conversion.
Q4: What operating information should I provide when requesting technical support?
For a screw refrigeration compressor service request, provide the operating pressures, temperatures, refrigerant, power supply conditions and protection alarm records. This helps technicians identify potential compressor-side and system-side problems.