Refcomp 105HP 78KW SW3L-10500 Low Temperature Refrigeration Screw Compressor
Refcomp SW3L-10500 screw compressor
,105HP low temperature screw compressor
,78KW refrigeration screw compressor
-
Flexible Capacity Regulation
The refrigeration screw compressor supports four-step capacity control at 25%, 50%, 75% and 100%, or stepless adjustment from 25% to full load, helping match compressor output to changing cooling demands.
-
Compact High-Pressure Housing
The semi-hermetic screw compressor features a 25-bar housing with optimized internal gas passages to reduce flow resistance. Its integrated construction accommodates key components for convenient system installation.
-
Star-Delta Motor Starting
The standard Y/Δ motor configuration supports star-delta starting to manage motor startup current. The electrical configuration is available for the specified three-phase power supply requirements.
-
Flexible Shut-Off Valve Configuration
The semi-hermetic refrigeration compressor features 360° rotatable suction and discharge shut-off valves for flexible piping arrangements. An internal discharge check valve helps prevent refrigerant backflow during shutdown.
| Parameter | Value |
|---|---|
| Model | SW3L-10500 |
| Rated power | 105HP / 78KW |
| Exhaust volume 50/60Hz | 341 / 409 m³/hr |
| Weight | 530 Kg |
| Capacity Regulation | 100%, 75%, 50%, 25% (stepless 100%–25%) |
| Standard motor | Y/Δ – 400V/3/50Hz – 460V/3/60Hz |
| LRA Y/Δ | 318 / 953 A |
| Max Operating Current | 163 A |
-
Q1: How can I confirm whether this compressor is suitable for my low-temperature application?
For refrigeration screw compressor selection, provide the required cooling capacity, refrigerant, evaporating and condensing temperatures, and operating frequency. The low-temperature screw compressor should be checked against manufacturer performance data at the actual operating conditions.
-
Q2: What should be checked before connecting the compressor to an existing refrigeration system?
Verify the suction, discharge and oil-line connections against the system piping drawings. Also check piping cleanliness, oil return arrangements and available maintenance space.
-
Q3: Can the compressor output adapt to changing refrigeration loads?
Yes. For an industrial refrigeration screw compressor installation, the available four-step or stepless capacity regulation can be selected according to the system load profile and controller compatibility.
-
Q4: What should I do if the motor protection module trips during operation?