Refcomp SP8L6000 SP8L600E 60HP Reciprocating Semi-Hermetic Compressor
60HP semi-hermetic reciprocating compressor
,SP8L6000 semi-hermetic refrigeration compressor
,SP8L600E reciprocating compressor 60HP
-
Eight-Cylinder Compression Design
The SP8L6000 reciprocating semi-hermetic compressor features eight cylinders, delivering a displacement of 222 m³/h at 50 Hz and 268 m³/h at 60 Hz.
-
Three-Stage Capacity Control
100%, 75% and 50% capacity regulation allows compressor output to match changing refrigeration loads, supporting flexible system operation.
-
Reliable Mechanical Construction
RefComp's crankshaft, connecting rods and pistons work with pressure-lubricated bearings to reduce friction and support stable operation.
-
Motor Protection and Starting
An INT69B2 motor protection module safeguards the motor, while partial-winding starting helps manage electrical demand during startup.
-
Integrated Service Components
The reciprocating semi-hermetic compressor incorporates a suction filter, service valves and a 200W crankcase heater to support system integration and maintenance.
| Parameter | Value |
|---|---|
| Model | SP8L6000, SP8L600E |
| Rated power | 60HP / 45KW |
| Exhaust volume 50/60Hz | 222/268 m³/hr |
| Cylinders | 8 |
| Weight | 345 Kg |
| Oil Charge | 5 L |
| Standard motor | 400V/3/50Hz, 460V/3/60Hz PW |
| Starting current PW/DOL | 371/361 A |
| Max operating current | 115 A |
Q1: What information is needed to select the SP8L6000 for a refrigeration system?
Selecting this reciprocating semi-hermetic compressor requires the refrigerant type, cooling capacity, evaporating and condensing temperatures, and operating frequency. These details help verify system compatibility and compressor performance under the required conditions.
Q2: What electrical requirements should be checked before installing the SP8L6000?
The standard motor supports 400V/3/50Hz and 460V/3/60Hz power supplies with partial-winding starting. Confirm the supply voltage, starting equipment, electrical protection and wiring configuration before installation.
Q3: What precautions should be taken before starting the SP8L6000 compressor?
Check the oil level, refrigerant piping, valve positions, electrical connections and crankcase heater operation. Complete leak testing and system evacuation according to the manufacturer's commissioning procedures.
Q4: How should the SP8L6000 be maintained during regular operation?
Monitor operating pressures, oil condition, motor current and vibration levels. Periodically inspect the suction filter, electrical connections and service valves, and investigate abnormal operating conditions promptly.