2CES-3-40S 3HP R22 Bitzer Semi Hermetic Compressor for Air Conditioning
3HP Bitzer Semi Hermetic Compressor
,R22 Semi Hermetic Compressor
,Bitzer Compressor for Air Conditioning
-
Optimized Valve Plate Design
The BITZER ECOLINE reciprocating compressor features optimized valve-plate geometry, reduced internal losses and lower pressure drops to improve compression efficiency. ECOLINE design improvements can deliver COP increases of up to 12% compared with the previous product generation.
-
Wear-Resistant Drive Components
A surface-hardened crankshaft, low-friction bearings, forged pistons and high-hardness alloy piston rings help this Bitzer semi hermetic compressor maintain stable mechanical operation and resist wear.
-
Low-Noise, Low-Vibration Operation
Balanced compressor mass distribution and a specially designed discharge cover help reduce exhaust pulsation and operating vibration, contributing to smoother and quieter operation.
-
Compact Installation Design
The compact semi-hermetic reciprocating compressor construction reduces installation space requirements, providing greater flexibility for refrigeration equipment layouts and replacement projects.
-
Alternative Refrigerant Version Available
The 2CES-3-40S is the R22 refrigeration compressor version. If your system uses R404A, R507A, R407A, R407C or R407F, the corresponding 2CES-3Y-40S is another option to consider. Both versions share the same basic specifications, with the refrigerant-specific version selected according to system requirements.

| Parameter | Value |
|---|---|
| Model | 2CES-3-40S |
| Rated power | 3HP |
| Displacement (1450/min) | 16.2 m³/hr |
| Oil charge | 1.5L |
| Weight | 70 Kg |
| Capacity Regulation | – |
| Standard motor | 220-240Δ/3/50, 265-290Δ/3/60 380-420Y/3/50, 440-480Y/3/60 |
| Max. operating current | 15.8/9.1 A |
| Max. power consumption | 5KW |

Consider the required cooling capacity, refrigerant, evaporating and condensing temperatures, ambient conditions and power supply. For low-temperature refrigeration compressor selection, verify the actual operating conditions rather than relying on displacement alone.
Variable-speed operation depends on the motor configuration and application limits. Confirm the permitted frequency range and inverter compatibility for the specific 40S motor before commissioning.
Compare refrigerant compatibility, oil requirements, piping connections, mounting dimensions and electrical arrangements. Also check whether the existing system's controls and protection devices are suitable for the replacement unit.
Monitor lubricant condition, operating temperatures, abnormal vibration and running noise. Regular inspections help identify potential wear or operating problems before they develop into major failures.