Bitzer 4DES-5-40S 4DC-5.2-40S 5HP Reciprocating Semi Hermetic Compressor
Bitzer 5HP semi hermetic compressor
,4DES-5-40S reciprocating compressor
,4DC-5.2-40S refrigeration compressor
-
Efficient Valve Plate Design
Optimized suction and discharge valve components and minimized clearance volume help reduce internal losses and improve compression efficiency. The valve plate uses high-strength spring steel for reliable operation.
-
Wear-Resistant Drive Components
A surface-hardened crankshaft, low-friction bearings, aluminum pistons and high-hardness alloy piston rings help reduce friction and mechanical wear during continuous operation.
-
Low-Noise, Low-Vibration Operation
Balanced compressor mass distribution and a specially designed discharge cover help reduce discharge pulsation and operating vibration, supporting smoother operation.
-
Flexible Capacity Regulation
The compressor is equipped with 50% capacity regulation, allowing the refrigeration system to better adapt to changing load conditions instead of operating continuously at full capacity.
| Parameter | Value |
|---|---|
| Model | 4DES-5-40S, 4DC-5.2-40S |
| Rated power | 5 HP |
| Displacement (1450/min) | 26.8 m³/hr |
| Oil charge | 2 L |
| Weight | 86 Kg |
| Capacity Regulation | 50 % |
| Standard motor | 220-240Δ/3/50, 265-290Δ/3/60 380-420Y/3/50, 440-480Y/3/60 |
| Max. operating current | 25.2/14.5 A |
| Max. power consumption | 8.1 KW |
Q1: What information should I provide when selecting this compressor for a refrigeration system?
Provide the required cooling capacity, refrigerant, evaporating and condensing temperatures, power supply and application conditions. These details are needed to confirm whether the compressor matches the actual system requirements.
Q2: Is there an alternative version for applications using other refrigerants?
If your system uses an alternative refrigerant instead of R22, 4DES-5Y-40S can be considered. The two versions have the same specifications and configuration, with the refrigerant being the only difference.
Q3: How can the compressor handle changes in system load?
The 50% capacity regulation allows the compressor's refrigeration output to be reduced when the system does not require full load. This can help the system respond more appropriately to varying cooling demand.
Q4: What should I check when replacing an existing compressor?
Confirm the refrigerant, required cooling capacity, electrical supply, oil requirements and suction/discharge connections. Installation dimensions and the actual operating conditions should also be checked before replacement.