Bitzer 4DES-7-40S 4DC-7.2-40S 7HP R22 Reciprocating Semi Sealed Compressor
Bitzer 4DES-7-40S semi sealed compressor
,7HP R22 reciprocating compressor
,semi hermetic refrigeration compressor
-
Optimized Valve Plate Design
Optimized suction and discharge valve components, together with minimized clearance volume, help reduce internal losses and improve compression efficiency. The valve plate uses high-strength spring steel for reliable mechanical performance.
-
Wear-Resistant Drive Components
A surface-hardened crankshaft, low-friction bearings, aluminum pistons and high-hardness alloy piston rings help reduce friction and mechanical wear in the reciprocating compressor.
-
Low-Noise, Low-Vibration Operation
Balanced compressor mass distribution and a specially designed discharge cover help reduce exhaust pulsation and operating vibration, contributing to smoother operation.
-
50% Capacity Regulation
The compressor provides 50% capacity regulation, allowing refrigeration output to be adjusted when the system does not require full capacity. This provides a practical way to match compressor output with changing cooling demand.
| Parameter | Value |
|---|---|
| Model | 4DES-7-40S, 4DC-7.2-40S |
| Rated power | 7HP |
| Displacement (1450/min) | 26.8 m³/hr |
| Oil charge | 2L |
| Weight | 89 Kg |
| Capacity Regulation | 50% |
| Standard motor | 220-240Δ/3/50, 265-290Δ/3/60 380-420Y/3/50, 440-480Y/3/60 |
| Max. operating current | 28.7/16.5 A |
| Max. power consumption | 8.9 KW |
Q1: What information should I provide for compressor selection?
Provide the required cooling capacity, refrigerant, evaporating and condensing temperatures, power supply and application conditions. These details help determine whether the selected compressor matches the actual system requirements.
Q2: How does the capacity regulation help in system operation?
The 50% capacity regulation allows the compressor to operate at reduced capacity when full refrigeration output is not required. This helps the system respond to changes in cooling demand.
Q3: What should I check when replacing an existing compressor?
Check the refrigerant, cooling requirements, electrical supply, oil charge and suction and discharge connections. Installation dimensions and the system's actual operating conditions should also be checked before replacement.
Q4: What should operators monitor during routine operation?
Monitor lubrication conditions, operating temperatures, vibration and running noise. Significant changes from normal operating conditions should be investigated to identify potential mechanical or system problems.