Bitzer 4FES-5-40S 4FC-5.2-40S 3HP Water Cooled Chiller Reciprocating Compressor
Bitzer 4FES-5-40S reciprocating compressor
,3HP water cooled chiller compressor
,semi hermetic refrigeration compressor
-
Optimized Valve and Clearance Design
The BITZER ECOLINE compressor features optimized suction and discharge valve components and minimized clearance volume, helping reduce internal losses and pressure drops. These design features are important when evaluating a chiller reciprocating compressor for efficient operation.
-
Wear-Resistant Drive Components
A surface-hardened crankshaft, low-friction bearings, aluminum pistons and high-hardness aluminum-alloy piston rings help reduce friction and mechanical wear in this four-cylinder reciprocating compressor.
-
Low-Noise, Low-Vibration Operation
Uniform compressor mass distribution and a specially designed discharge cover help reduce exhaust pulsation and operating vibration, contributing to smoother and quieter operation.
-
50% Capacity Regulation
The 4FES-5 can be equipped with 50% capacity unloading, allowing refrigeration output to be reduced when full cooling capacity is not required. This provides greater flexibility for partial-load operation.
| Parameter | Value |
|---|---|
| Model | 4FES-5-40S |
| Old model | 4FC-5.2-40S |
| Rated power | 5 HP |
| Displacement (1450/min) | 18.1 m³/hr |
| Oil charge | 2 L |
| Weight | 86 Kg |
| Capacity Regulation | 50 % |
| Standard motor | 220-240Δ/3/50, 265-290Δ/3/60 380-420Y/3/50, 440-480Y/3/60 |
| Max. operating current | 18.8/10.8 A |
| Max. power consumption | 5.8 KW |
-
Q1: What information should I provide when selecting a chiller reciprocating compressor?
Provide the required cooling capacity, refrigerant, evaporating and condensing temperatures, ambient conditions and power supply. These details help determine whether the compressor matches your chiller application.
-
Q2: Can this chiller reciprocating compressor operate at reduced capacity?
Yes. The 4FES-5 can be equipped with 50% capacity unloading to accommodate reduced cooling demand. Confirm the required capacity-control configuration when placing your order.
-
Q3: What should I check when replacing an existing compressor?
Check refrigerant compatibility, electrical connections, lubricant requirements, piping dimensions and installation space. The replacement should also match the existing system's operating conditions.
-
Q4: What maintenance should operators pay attention to?
Monitor lubrication conditions, operating temperatures, vibration and running noise. Regular inspections help identify abnormal operating conditions and potential mechanical wear.